Quick answer
A fuse for a continuous load is sized at 125 percent of that load and rounded up to the next standard rating. A 40A continuous draw needs 50A of overcurrent protection, and the conductor must be rated to carry at least that.
Result
The formula
fuse amps = continuous amps x 1.25, rounded up to the next standard size
A fuse protects the WIRE, not the appliance. Sizing the fuse above the conductor ampacity defeats the entire point of fitting one.
The figures shown above are computed with these exact inputs: Continuous load 40 A, Sizing factor 1.25.
Some of these are published standards and some are conventions. They are not the same kind of number, so each one is labeled.
| Assumption | Kind | Where it comes from |
|---|---|---|
| Continuous Load Factor: 1.25 | Published standard | NEC 210.20(A), overcurrent device sized at 125 percent of a continuous load |
| NEC Table 310.16 | Published standard | NEC Table 310.16, 75 C copper |
Every card below is in the page source. The calculator re-ranks them against your numbers and marks anything that falls short of what you just calculated.
Takes 0 through 4 AWG, which covers the cable sizes an RV inverter circuit actually uses.
Best for: Fusing an inverter feed at the battery.
Check price on Amazon
Three holders in one pack, which is usually what a full build needs once the inverter, the solar and the DC-DC feed are all fused.
Best for: Fusing several circuits in one build.
Check price on Amazon
A sealed body with matched input and output gauges, which keeps the fuse holder from becoming the weak point in the run.
Best for: A tidy inline fuse on a heavy cable.
Check price on AmazonResearched guidance, not professional advice. These results are planning figures from published standards and manufacturer specifications. Never exceed a conductor's rated ampacity, fuse every positive conductor close to the battery, never run a generator in an enclosed space because carbon monoxide is lethal and odorless, and have permanent AC wiring done by a qualified RV technician or licensed electrician.